Surge Suppressor

Surge Suppressor
Product Detailed
1. Surge Suppressor 2. Un: 5V, Uc: 8V 3. Up: <50V, In: 5kA 4. Connection mode: Wiring terminal 5. Transmission rate: 2M

LDY-C/P Surge Protective Device

Application range

LDY-C/P series SPD for control signal are applied to the front-end of control signal system, providing overvoltage protection arising from surge to control signal line or misoperation. (Option from standard IEC61643-21 and GB50343)

 

Main features

Modularization design, wiring terminal connection, convenient for installation and replacement;Adopt multilayer protection technology, strong protection ability, high reliability;Build-in earthing terminal, strong wiring ability, more reliable earthing;High current capacity and low output residual voltage.

 

Main technical data

Type

LDY-C/P5

LDY-C/P12

LDY-C/P24

LDY-C/P36

Nominal Operating voltage Un

5V

12V

24V

36V

Max. continuous operating Voltage Uc

8V

18V

36V

54V

Voltage protection level Up

< 50V

< 50V

< 80V

< 80V

Nominal discharge current In (8/20μs)

5 kA

Connection mode

Wiring terminal

Transmission rate Vs (bit/s)

2M

Insertion loss dB

≤0.5

Housing material

Enhanced flame retardant nylon

(light gray, flame retardancy degree: V0)

Installation pattern

35mm standard DIN rail installment

Cross-section

≥ 2 mm2 stranded/flexible conductor

Installation instruction

1. The SPD is connected in series between the signal channel and the protected equipment.

2. Connect the input terminal to the signal channel, and the output terminal to the protected equipment.

3. Connect the earthing wire of SPD to the equalizing ring of the surge protection system.

4. The SPD is needless for special maintenance. When it is suspicious of SPD fault in system operation, please dismantle SPD module and then check. If the system recovers normality, SPD has broken down and needs replacement. During replacing SPD module, circuit will not be cut off and be in normal working.

 

Surge Suppressor



Copyright Notice @ 2008-2022 ECOL Limited and/or its subsidiaries and licensors. All rights reserved.